e⚡TruckTCO BE

Home › Specifications › Kempower Satellite

Kempower · Charger sheets

Kempower Satellite

The Kempower Power Unit with Satellite dispensers, the low-loss split-DC system the eTRUCKTCO calculators pick by default for fleets up to 80 trucks: up to 400 kW per plug, up to 12 charging points on one Power Unit and 1,200 kW with two Power Units; on the Kempower stand in Hall 13.

Kempower SatelliteImage: Kempower
35 of 43 values are filled in. Know one we are missing, or one that is wrong? This sheet is open for anyone to correct — type into it on eTRUCKTCO.eu, press Review & send, and confirm the e-mail. It is on all three sites the moment we have checked it. Correct or complete this sheet

Company 4 / 4

CompanyLegal nameKempower Oyj↗
HeadquartersCity, countryLahti, Finland↗
Parent groupListed on Nasdaq Helsinki↗
Websitekempower.com↗

IAA Transportation 2026 4 / 5

Hall and stande.g. Hall 13, Stand C26Hall 13, Stand C26↗ ↗
Premiered in HanoverWorld or European premieres on the standnot published
Charging products on the standModels shownKempower Satellite, Liquid-Cooled Satellite, Power Unit, Control Unit, Mega Satellite Flex, ChargEye charging-management software↗
Announcements at the showPartnerships, orders, launch datesTalk "The Next Phase of Truck Charging: Insights from Real-World Operations" by Antti Vuola, VP of Product, on the Industry Stage (Hall 13), 17 September 2026, 14:00–14:45. On 15 September 2026 Kempower extended its sales and service partnership with Charge Hub to the UK↗ ↗
Who to talk to on the standAs listed on Kempower's profile in the organiser's exhibitor directoryKris Meskens, Sales Manager Belgium & Luxembourg; Han Dix, Country Manager Benelux; Stanislaus Gierszewski, Sales Manager Transport & Logistics DACH↗

The charging system 16 / 19

ModelProduct name as soldKempower Satellite, fed by the Kempower Power Unit↗
ArchitectureSplit DC (power cabinet + dispensers) or all-in-oneSplit DC: Power Unit cabinet with dynamic power sharing, Satellite dispensers on cables, modular 50 kW power blocks↗ ↗
Power per cabinet or unitLargest single Power Unit (triple cabinet, twelve 50 kW modules); 450 kW also offered, single and double cabinets up to 400 kW. Two Power Units in parallel give 800 or 1,200 kW600 kW↗
Power-sharing stepPower moves between charging points in 25 kW steps; the power modules themselves are 50 kW. Earlier: 50 (eTRUCKTCO calculators, which count in 50 kW modules)25 kW↗
Outlets per power unitDispensers or plugs one cabinet can feedUp to 12 charging points on a 450 or 600 kW Power Unit, up to 8 on single and double cabinets; each Satellite has one or two plugs↗ ↗
Max power per CCS outletPer plug, at 500 A and 800 V; 300 kW at the continuous 375 A400 kW↗ ↗
Max current, CCS500 A for at most 15 or 50 minutes at +25 °C, depending on the version; 375 A continuous. Needs several Power Unit outputs joined together500 A↗ ↗
Megawatt Charging System (MCS)The Satellite has CCS2 or CHAdeMO plugs only; the same Power Units also feed the Mega Satellite Flex, which has MCS (see its sheet)no↗
Max power per MCS outletnot published
Max current, MCSMCS connector allows up to 3,000 Anot published
Output voltage rangeMaximum1000 V↗
Efficiency, grid to plugPower Unit at full load, datasheet of March 2023 (C800); Kempower hands out newer datasheets only after a form on its website94 %↗
Loss grid to battery, overnight depotAs assumed in the eTRUCKTCO calculators≈ 8 (split DC, low loss) %↗
CoolingLiquid-cooled cables / airLiquid-cooled cables on the Liquid-Cooled Satellite (500 A, 400 kW or more, for trucks and buses, with a 600 or 1,200 kW Power Unit); the Power Unit cabinet is air-cooled (air inlet and outlet)↗ ↗
Cable lengthCharging cable length options; the Satellite can stand up to 80 m from the Power Unit. Versions with 7 m cables weigh 2 kg more5 / 7 m↗
Protection and temperature rangePower Unit figures from the March 2023 datasheetIP54, IK10; -30 to +55 °C, less current above +40 °C (Satellite). Power Unit: IP54, IK10, -30 to +50 °C↗ ↗
NoiseLess than 60 dB at 1 m, Power Unit (datasheet of March 2023)60 dB↗
Battery bufferBuilt-in storage to soften the grid peak, if anynot published
Size and weightPower Unit figures from the March 2023 datasheetSatellite 300 × 1,738 × 300 mm (W × H × D), 76–176 kg by version; Power Unit 650, 1,250 or 1,850 mm wide (single, double, triple cabinet) × 2,195 mm high × 841 mm deep, 280–1,200 kg↗ ↗

Software and standards 4 / 4

OCPPVersion1.6J and 2.0.1↗ ↗
ISO 15118 / Plug & ChargeISO 15118-2 Plug & Charge and AutoCharge; ISO 15118-1 and DIN 70121 on CCS2↗
Load and fleet managementDynamic power sharing, depot peak controlDynamic power management: a Power Distribution Module in each Power Unit moves power in 25 kW steps to the charging points that need it↗
Software offeredBack-end, app, monitoringChargEye charging management (remote monitoring and customisation); Ethernet; 7-inch touch screen, RFID, backend via OCPP, optional payment terminal↗ ↗

Buying and running it in Europe 4 / 8

List pricePer cabinet or per outlet, say whichnot published
Price per kW installedHardware only or turnkey, say whichnot published
Availability in EuropeOrder now, deliveries from …On sale. In April 2025 Kempower planned deliveries of the 1,200 kW ("More Power") set-up from the second quarter of 2025 and of the 12-plug ("More Plugs") set-up from early in the fourth quarter of 2025↗
Units delivered in Europe to datenot published
Reference customers in EuropeFleets, operators, hubsUK: five South London bus depots (Bexleyheath, Croydon, Sydenham, Thamesmead, Peckham) are the first projects of Charge Hub, which uses Kempower as its hardware partner (September 2026)↗
WarrantyYears, service levelsnot published
Service network in EuropeOwn technicians, partners, response timeService packages with remote monitoring and diagnostics; Kempower says 80 % of issues are solved remotely↗
Turnkey partnersWho installs it, including the grid connectionUK: Charge Hub, Kempower's sales and service partner, does site design, installation, operation and maintenance↗

On this site 3 / 3

In the eTRUCKTCO calculatorsWhich option, and with what loss and cost factorYes: "Kempower Satellite · split DC · 8 % loss", hardware factor 0.94; the automatic choice for fleets up to 80 trucks↗
Trucks on this site it can charge at full powerSee the truck sheetsEvery truck of the T&E comparison except the DAF XG Electric is MCS-capable or announced so (MAN eTGX up to 750 kW): see the truck sheets at /sheets/avs/↗
Anything else worth knowingThe MCS dispenser for the same Power Units, the Mega Satellite Flex, has a sheet of its own on this site↗

Where these figures come from